Hotel Door Lock Maintenance: 19 Tips Maintain Hotel Door Lock Well

The popularity of RFID hotel door locks has been relatively high. Hotels in many places have installed RFID hotel door locks, facilitating the hotel RFID locks' management and maintenance and dramatically improving the hotel's overall style. Most hotels now use smart door locks.

Hotel Door Lock Maintenance 16 Tips Maintain Hotel Door Lock Well - Hotel Door Lock Maintenance: 19 Tips Maintain Hotel Door Lock Well

Why Do You Need Hotel Door Lock Maintenance?

Compared with traditional door locks, hotel RFID locks have many advantages, but the RFID hotel door lock maintenance is more delicate than conventional door locks. Hotel smart hotel RFID locks belong to hardware and machinery, and the general warranty is two years.

At present, this technology is relatively mature and crashes rarely occur. The hotel smart door locks must be more intelligent, but if you can do hotel RFID locks maintenance work well, it will extend the RFID hotel door lock's service life.

High-quality hotel card lock products and stable hotel door lock systems will make the product life longer, reducing maintenance costs, and saving several labor costs, maintaining the hotel's overall image. So how to maintain hotel RFID locks?

Hotel Door Lock Maintenance-Main Parts.

The main parts of smart RFID hotel door locks generally include lock panels, mechanical lock cylinder, lock mortise, mainboard, and battery pack.

Tips 1. Hotel door Lock Panel maintenance

The hotel rf card lock panel includes a front panel and a rear panel. The hotel door lock handles often fail here.

resize,m fill,w 966,h 644# - Hotel Door Lock Maintenance: 19 Tips Maintain Hotel Door Lock Well

It is recommended to add butter to the door lock handle spring every year. If the transmission part of the lock body has lubricant, the handle will not get stuck.

Its transmission will be smooth, and its service life can be extended. At the same time, check whether the panel fastening screws are loose to ensure they are tight.

Tips 2. The Hotel door lock mechanical cylinder maintenance

In the process of using the hotel key card lock, the mechanical lock cylinder is rarely used. Regular room guests use the room key card to open the door. It has been needed as a backup method of opening the door from time to time. Under particular circumstances, the key will be used to open the door.

resize,m fill,w 868,h 548# - Hotel Door Lock Maintenance: 19 Tips Maintain Hotel Door Lock Well

It is recommended to perform mechanical lock cylinder maintenance every year or when the key is not smoothly inserted and removed. You can put a small amount of graphite powder or pencil powder into the lock cylinder slot and plug it back and forth to make the key insertion and removal smooth.

However, do not add any other oil as a lubricant. This will cause the grease to stick to the pin spring, causing the lock not to rotate and not open.

Tips 3. Hotel door lock battery pack maintenance:

The hotel smart key card lock uses 1.5V 4 AA batteries. When the battery is lower than 4.7V, the hotel door lock will alarm, and the battery needs to be replaced.

resize,m fill,w 926,h 612# - Hotel Door Lock Maintenance: 19 Tips Maintain Hotel Door Lock Well

It is recommended to replace the battery every 18 months.

Tips 4. Hotel door lock mainboard and lock mortise maintenance:

The mainboard and lock mortise maintenance are the most important of RFID hotel door locks maintenance.

When it appears that the door lock has been closed, press the handle firmly, and the door opens again. At this time, the lock mortise needs to be replaced.

Hotel door lock mainboard and lock mortise maintenance - Hotel Door Lock Maintenance: 19 Tips Maintain Hotel Door Lock Well

It is recommended to replace the same model's lock mortise from the original factory, and there is no need to adjust the lock clock and replace it directly.

In the second renovation of the hotel, you can also consider replacing the RFID hotel door locks motherboard.

Tips 5:  Frequently check the fit-gap between the hotel door lock mortise and the lock strike.

Check the height fit between the lock bolt and the lock strike plate's hole and whether it is suitable for long-term use. The best gap between the door and the door frame is 1.5mm--3.5 mm.

resize,m fill,w 1090,h 624# - Hotel Door Lock Maintenance: 19 Tips Maintain Hotel Door Lock Well

If any changes are flocking hinge positioning hinge or the locking plate on the door should be adjusted.

At the same time, pay attention to the cold shrinkage and thermal expansion caused by the weather (wet in spring, dry in winter) to ensure that the gap between the door and the door frame, the lock mortise, and the lock strike plate is reasonable, and the lock is used smoothly.

Tips 6. The hotel RFID locks installation operation must be correct.

When installing hotel RFID locks, the handle and panel must not be pasted with paper or tape. Do not install the lock when the paint on the door is not dry. It is forbidden to contact the lock surface with corrosive substances to damage the lock surface's protective layer and affect its gloss.

Tips 7. Use special door lock maintenance liquid to wipe spots

Some zinc alloy and copper hotel RFID locks will find "spots" after being installed on the door for a long time during use. This phenomenon is not rust but oxidation. If this happens, Spray the door lock maintenance liquid to remove the spots.

resize,m fill,w 1388,h 548# - Hotel Door Lock Maintenance: 19 Tips Maintain Hotel Door Lock Well

Tips 8. Do not wipe the door lock panel and handle with a damp cloth to avoid oxidation.

It is recommended to use the hotel RFID locks maintenance liquid to remove the surface dirt, make the door lock surface smooth and moist, form a protective effect on the surface, improve the continuity of surface cleanliness, and make the surface as clean as new!

Tips 9. Keep the hotel RFID locks deadbolt safe when decoration.

During the decoration period, please do not play the locked deadbolt for a long time. If you close the door after playing the lock deadbolt, it will easily damage the lock deadbolt!

Keep the Hotel door lock deadbolt safe when decoration - Hotel Door Lock Maintenance: 19 Tips Maintain Hotel Door Lock Well

Tips 10. Test hotel card lock with mechanical key

After installing the hotel card lock, please test it with a mechanical key. The door can be opened and closed normally.

Tips 11. Keep the mainboard and lock mortise of hotel ock not wet.

The mainboard and the hotel card lock's lock mortise should not be exposed to rain and water ingress because of the fine structure, which will cause inflexibility or damage.

resize,m fill,w 1016,h 570# - Hotel Door Lock Maintenance: 19 Tips Maintain Hotel Door Lock Well

Tips 12. The door buckle plate's installation position must be correct, and the oblique tongue of the lock body cannot be pressed. Otherwise, the door lock will "di...di..." alarm.

Tips 13. It is recommended to use alkaline batteries for hotel card locks.

Significantly even low battery leakage may damage the smart hotel lock. It is recommended to use alkaline dry batteries (expensive, high capacity, not easy to leak), do not use dry carbon batteries (cheap, low power, easy to spread).

Tips 14. Replace hotel key card lock batteries in time.

After the low battery alarm, please replace the hotel card lock battery immediately to ensure the door lock's regular use.

Tips 15. Use new hotel lock batteries.

Note that no matter how many batteries are in your battery compartment, please make sure to replace all batteries with new ones, and you cannot use old and new batteries together.

resize,m fill,w 1108,h 554# - Hotel Door Lock Maintenance: 19 Tips Maintain Hotel Door Lock Well

Tips 16. The mechanical key must be appropriately kept.

Tips 17. Issue a "time card" regularly (every two months) to maintain the hotel key card lock.

Tips 18. To ensure the hotel card lock system database's security, system operators should regularly back up the system database files.

Tips 19. Please use plastic bags to seal the hotel door lock, handles panels, and other exposed parts during the hotel room renovations. Acidic or alkaline substances will cause the electronic door lock to corrode gas, and blistering will cause delamination. Affect the appearance of the quality of the electronic door lock.

Other Recommended Popular Articles

Fingerprint Door Lock Price 1 - Hotel Door Lock Maintenance: 19 Tips Maintain Hotel Door Lock Well
What Is a Fingerprint Door Lock 1 - Hotel Door Lock Maintenance: 19 Tips Maintain Hotel Door Lock Well
Top 20 Question to Ask Before Buying Smart Door Locks - Hotel Door Lock Maintenance: 19 Tips Maintain Hotel Door Lock Well